Ductile Iron Manhole Cover Weight Chart

Real complete-set weights — cover + frame — from more than 1,000 tooling sets in our pattern shop: 804 round-cover molds and 256 square/rectangular molds, from Ø400 footway covers to Ø900 heavy-duty sets. No catalog guesswork: these are numbers off actual production molds.

By the Keyuda Casting engineering team · Updated November 2026

Ask three suppliers for the weight of a "700 mm D400 manhole cover" and you may get three different answers. All three can be right — because weight is driven by frame design, not just by clear opening. This chart is built from our production records: 804 round-cover molds and 256 square/rectangular molds, of which 502 carry a verified cover/frame weight split. It explains exactly what makes the same nominal size heavier or lighter.

Why weight matters more than size

Ductile iron manhole covers are almost universally priced by theoretical weight (total set weight × unit price per kg, plus machining/coating). Weight also drives your landed cost: freight, port handling and inland haulage all scale with kilograms. A buyer who can't read the weight column of a quotation can't actually compare quotations.

How deep our tooling goes

Before individual weights, here is the coverage behind them. Our pattern shop holds 804 round-cover molds and 256 square/rectangular molds — over a thousand tooled sets, from Ø300 footway covers to Ø1000 heavy-duty and airport-class covers. The table below summarises the weight band in tooling for each standard nominal size (10th–90th percentile of our molds, so one-off specials don't skew the picture).

Nominal sizeMolds in toolingTypical complete-set weightTypical set height
Ø400 round3719–63 kg22–70 mm
Ø500 round4826–115 kg30–100 mm
Ø600 round6634–110 kg28–160 mm
Ø650 round6046–90 kg20–125 mm
Ø700 round16745–100 kg21–150 mm
Ø750 round10771–132 kg22–150 mm
Ø800 round3155–110 kg27–120 mm
Ø900 round17105–189 kg30–160 mm
Ø1000 round1085–178 kg50–150 mm
Square 3001913–38 kg—
Square 4001715–50 kg—
Square 4501830–73 kg—
Square 5001520–80 kg—
Square 6002725–122 kg—
Square 7001730–100 kg—
Square 800570–110 kg—

Weight bands are complete-set weights (cover + frame) from production mold records. Load class is confirmed per drawing and test report — the same nominal size is tooled in footway (A15/B125), carriageway (C250/D400) and heavy-service (E600+) versions.

Representative sets — cover weight vs frame weight

For each diameter below we list three real molds from our records: the lightest, a mid-range and the heaviest version in tooling. The split between cover weight and frame weight is what actually differs between quotations.

Cover ØFrame outer ØSet heightCover weightFrame weightComplete set
Ø500Ø57045 mm11 kg6 kg18 kg
Ø500Ø620100 mm25 kg16 kg42 kg
Ø500Ø95596 mm41 kg35 kg80 kg
Ø600Ø60036 mm18 kg7 kg25 kg
Ø600Ø80055 mm35 kg20 kg55 kg
Ø600Ø820110 mm58 kg49 kg105 kg
Ø650 (square-outside)715 × 71580 mm23 kg19 kg41 kg
Ø700Ø79849 mm19 kg9 kg28 kg
Ø700Ø880100 mm40 kg27 kg65 kg
Ø700 (anti-settlement)Ø1200108 mm56 kg93 kg150 kg
Ø750Ø850100 mm44 kg22 kg65 kg
Ø750 (anti-settlement)Ø930190 mm52 kg50 kg103 kg
Ø800Ø90052 mm33 kg17 kg50 kg
Ø800 (anti-settlement)Ø985190 mm63 kg61 kg125 kg
Ø900Ø108080 mm55 kg34 kg90 kg
Ø900Ø1040150 mm100 kg60 kg160 kg

All figures are cast weights from production records; cover + frame equals the complete-set weight shown. Coating (bitumen, epoxy or paint) adds 1–3% on top. Gloss or paint finish is quoted separately.

Why two "Ø700" covers can differ by more than 100 kg

In our own tooling, Ø700 covers range from 28 kg to 150 kg complete — across 167 molds. The difference is not the diameter. It is the frame design and the duty class:

Practical takeaway: when comparing quotations, never compare "price per set" without the weight and the frame drawing. A cheap set can simply be a light frame that will not carry D400 traffic in practice — see our article on EN124 D400 load classes.

How to read weight on a quotation like a pro

  1. Confirm what's included. Weight should be the complete set: cover + frame + hardware. "Cover only" figures are typically 35–45% of set weight.
  2. Ask for theoretical weight with the drawing. Reputable foundries calculate weight from the 3D model minus draft, then quote per kg.
  3. Check the height. A set quoted 15% lighter at the same class usually means a shorter frame — fine for some installations, a problem for concrete-surround anti-settlement projects.
  4. Balance class and weight. Choose the lowest EN124 class that covers the real traffic (see the class table in our D400 article); overspecifying buys kilograms you don't need.

Gully gratings and trench covers

The same logic applies to drainage products: our gully grating line has 100+ tooled sizes with hinged frames, from B125 footway gratings to D400 trench covers made to length. Weights range from a few kilograms (small footway gratings) to over 80 kg for large road-side sets with deep frames.

Need weights for your size schedule? Send us your list of sizes and classes — we will reply with per-set weights and an FOB Qingdao quotation within 24 hours. Get a quote → or WhatsApp +86 188 3560 9139.

Related reading

← Back to Blog
Get a Quote